[Aritomi, Eleonora, Matteo]
To reduce the effect of locking accuracy, we reduced green power from 40mW to 25mW.
OPO temperature: 7.172 kOhm, p pol PLL: 200 MHz
Then we measured FDS. CC2 demodulation phase is 20deg for anti squeezing and 130deg for squeezing.