Attached figure is FDS curve with correct detuning (54Hz). With following parameters, frequency at which squeezing crosses shot noise is around 120Hz and frequency at which anti squeezing crosses shot noise is around 45Hz.
sqz_dB = 8; % produced SQZ
L_rt = 150e-6; % FC losses
L_inj = 0.20; % Injection losses
L_ro = 0.10; % Readout losses
A0 = 0.05; % Squeezed field/filter cavity mode mismatch losses
C0 = 0.05; % Squeezed field/local oscillator mode mismatch losses
ERR_L = 8.5e-12; % Lock accuracy [m]
ERR_csi = 80e-3; % Phase noise[rad]
phi_Hom = [0/180*pi, 10/180*pi, 20/180*pi, 30/180*pi, 40/180*pi, 50/180*pi, 70/180*pi ,90/180*pi]; % Homodyne angle [deg]
det = -54; % detuning frequency [Hz]