Attached figure is theoretical CCFC FDS curve with optimal detuning (54Hz). With the following parameters, frequency at which the anti squeezing crosses shot noise is 44Hz.
sqz_dB = 10.5; % produced SQZ (dB)
L_rt = 120e-6; % FC losses
L_inj = 0.35; % Injection losses
L_ro = 0.24; % Readout losses
A0 = 0.05; % Squeezed field/filter cavity mode mismatch
C0 = 0.05; % Squeezed field/local oscillator mode mismatch
ERR_L = 1e-12; % Lock accuracy (m)
ERR_csi = 30e-3; % Phase noise (rad)
phi_Hom = [0/180*pi, 30/180*pi, 60/180*pi ,90/180*pi]; % Homodyne angle (rad)
det = -54; % detuning [Hz]