For detuning around 200Hz data, the fit result of generated squeezing level and optical losses are
sqz | loss | |
data1 | 11.1 | 38.3 |
data2 | 11.2 | 39.9 |
data3 | 11.1 | 39.9 |
data4 | 10.8 | 37.4 |
data5 | 10.6 | 37 |
data6 | 10.5 | 42 |
For detuning around 70Hz data, the fit result of generated squeezing level and optical losses are
sqz | loss | |
data1 | 10.7 | 40.6 |
data2 | 10.4 | 40.6 |
data3 | 10.4 | 40.4 |
data4 | 10.0 | 37.5 |
data5 | 9.6 | 36.8 |
data6 | 10.0 | 37.1 |