Michael and Yuhang
We have measured residual amplitude modulation (RAM) for green beam using the reflection from GRMC.
We use a DC PD to monitor the GRMC reflection power. An RF PD in reflection of GRMC is used for measuring RAM.
We performed PD spectrum measurement several times for different green power going into PD. The result is shown in Fig.1.