We did measurement with input polarization angles of 0 deg, 15 deg and 30 deg.
We computed delta n and theta from them.
Especially, we found that theta = 1.6 deg in the center of the mirror.
This is exactly the value we expected from the HWP rotation angle.
We will use this rotation of the mirror for the polishing.