MatteoLeonardi - 16:16, Tuesday 10 April 2018 (737)
Comment to Comparison between the old and the new laser frequency servos (Click here to view original report: 736)

Following the discussion we had offline, I upload a measurement that was done few years ago when I was in the Padova group. The measurement is a characterization of the laser PZT gain as function of the frequency.
The laser is a 1W Mephisto laser from Coherent.

Images attached to this comment