NAOJ GW Elog Logbook 3.2

[Aritomi,Yuhang,Yao-chin, Eleonora]
The attached plot shows a very tentative degradation budget for the squeezing injection into FC detuned at 50 kHz (entry #1751)
PRODUCED SQUEEZING: 16 dB (from anti squeezing measurement) (entry #1587)
TOTAL INJECTION LOSS = 33 %
- from inside OPO to 1st PBS = 18% (loss of frequency independent squeezing: 21% - visibility: 2% - quantum efficiency: 1%)
- after 1st PBS before PR chamber = 10%
- from PR viewport up to FC = 5 %
TOTAL READOUT LOSS = 12 %
- from FC to PR viewport: 10%
- after viewport to Homodyne: 1%
- Homodyne Q. E. = 1%
MISMATCH from SQZ to FC = 10 %
MISMATCH from SQZ to HOM = 5 %
FILTER CAVITY LOSSES : 100 ppm
PHASE NOISE = 100 mrad (very tentative, when CC2 doesn't unlock)
LOCK ACCURACY = 5 pm (very tentative, to be measured)
Conclusion: it seems that the degradation is dominated by mismatching