YuhangZhao - 01:25, Saturday 15 February 2020 (2039)
detuning change for the measurement of FDS during more than one hour
Eleonora and Yuhang
We fixed the CC2 demodulation phase and measure FDS during more than one hour.
During these measurement, filter cavity got unlock twice. Also, for the last measurement, we misaligned filter cavity yaw.
The detuning was stable within ~10min. Even without unlock, detuning changes and unlock almost doesn't change detuning if green is recovered. But detuning will change after a bit misalignment.
Images attached to this report
Comments related to this report
Thank you for the measurement.
Can you add the fitting result of homodyne angle?
This is my fitting result.