R&D (FilterCavity)
Print this report.
EleonoraPolini - 11:55, Tuesday 21 May 2019 (1366)Get code to link to this report
Injection telescope with lenses we have in the lab

I found two good options using the lenses we already have in the lab.

Version 2:

1000 mm @ z = 0.517 m (distance from PBS)

750 mm @ z = 0.618 m

Version 3:

750 mm @ z = 0.42 m

750 mm @ z = 0.673 m

As we can see in fig 2 and fig 4, the robustness is not as good as the one of entry #1365 (fig 5), but we are still under 10% of mismatch.

In fig 6 there is the scheme on the bench of version 2 (PURPLE) and version 3 (BLUE).

Images attached to this report
1366_20190521045408_injv2.png 1366_20190521045435_injv2.png 1366_20190521045503_injv3.png 1366_20190521045519_injv3.png 1366_20190521045532_injv1.png 1366_20190615124554_versione2e3new.png