EleonoraCapocasa - 15:35, Monday 28 October 2019 (1774)

Simulation of the HOM output for different detection angles
I adapted the code to simulate the squeezing degradation in the case of standalone filter cavity. Basically, I removed the transfer matrix accountig for ITF in the quantum noise computation.
Now if we select a homodyne detection angle the code should simulated what we exepected to see when taking the spectrum of the Homodyne output.
In the code I also removed the approximation of small detuning and I simulate a large detunig case (50kHz) as the one we tested recently. (Entries: #1747, #1751)
Plot 1 shows the expected results for Homodyne angle: 0 deg and 90 deg. Plot 2 shows an intermediate case (30 deg) compared to the 0 deg case.
The degradation parameters are the same reported in entry #1766.